The Model 1575 Pressure Display is a low cost microprocessor based, digital display and set-point controller for the Barocel 600, 622 and 655 capacitance manometer. The Model 1575 incorporates power supply, digital display, four user-selectable set-points, along with analogue and optional RS232 output in a compact 1/8 DIN package.

Edwards Model 1575 Pressure Display

Features & benefits
  • Push button or remote zero adjustment
    - To adjust the transducer zero, simply press the front panel membrane switch. Alternatively, earth (ground) a rear panel connection.
  • Push button full scale calibration
    - Use the full scale calibration feature if you want to display engineering units which are different from the transducer calibration, or to incorporate arbitrary coefficients for the transducer.
  • User selectable set-points with open collector contacts
    - There are four user programmable solid-state, open collector set- points; two high and two low. The hysteresis band associated with each set-point can also be adjusted to meet system requirements.
  • Easy to read LED display
    - The 10 mm bright red, high efficiency LED display is easily visible from normal viewing angle; and in most lighting conditions.
  • Optional RS232 output
    - An RS232 port is available at minimal costs for digital pressure output

Edwards Model 1575 Pressure Display

TECHNICAL DATA

Signal input: ± 10 V d.c.
d.c. output: Transducer input signal
A/D resolution : ± 25000 counts
Accuracy: ± 0.005% of reading 2: 1. ± 2 counts
Full scale temperature coefficient : 20 ppm/ °C
Zero temperature coefficient: 001 ppm/ °C
Zero suppression : ± 100% of full scale
Transducer supply: ± 15 V d.c. at 250 mA (maximum)


Electrical supply (50 - 60 Hz)

Standard: 230 V a.c. ± 10%
Optional: 115 V a.c. ± 10%


Set-points (4 open collector transistors)

Voltage (maximum) 50 V
Current (maximum) 100 mA
Hysteresis (both set-points) 0 - 99 counts
Control status
: LEDS indicate controls actuated


Temperature range

Operation: +0 -55 °C
Storage: -40 to +85 °C
Warm-up time (at 25 *C): 30 minutes

Standards
Electronic design: EN 61010-1
Electromagnetic compatibility EN 61326 Industrial Location Class A Emissions

List of compatible transducers
Barocels 600, 622, 655

Edwards Model 1575 Pressure Display

Ordering Information

Edwards Model 1575 Pressure Display

Product Description

Edwards Model 1575 Pressure Display

Ordering Number
Model 1575 Pressure Display

analogue output 115 V
RS232 output 115V
analogue output 230 V
RS232 output 230V

Accessories
Cable (15ft, 4.5m)
Barocel 600
Barocel 622
Barocel 600 ('D' connector versions), 655

Electrical supply cables
2 m UK plug
2 m USA plug
2 m Northern European plug


W60810000
W60810004
W60820000
W60820004



W18997005
W18999005
W18992005


D40013025
D40013120
D40013030

Edwards Model 1575 Pressure Display

Gauge and controller installation examples

The Active range of vacuum gauges and controllers gives you the flexibility to design and configure a system which will fulfil your needs precisely. Our technical support team is on hand to advise you on the best system for your application. Examples of typical systems are shown below.

Item Quantity Ordering number Description Edwards Model 1575 Pressure Display
A
B
C
D
1
1
2
2
D39565000
D40013025
D02141000
D40001030
AGD for APG-M
UK electrical supply cable
APG-M
3 m Active Gauge cable


Item Ordering number Description Edwards Model 1575 Pressure Display
A
B
C
D
E
F
G
D39700000
D40013025
D02171000
D04850000
D35728000
D40003060
D40001303
TIC inst 3 head RS232
2 m UK mains cable
APGX-M-NW16 AL
AIGX-S-NW25
ASG NW16 2000 mbar
0.5 m ASG adaptor cable
3 m Active gauge cable


Item Ordering number Description Edwards Model 1575 Pressure Display
A
B
C
D
E
F
G

H
J
K
L
M
D39700000
D40013025
D02171000
D14641000
D14701000
D04850000
D40001010
D39700834
N/A
D39700804
D39700833
D39700833
TIC inst 3 head RS232
2 m UK mains cable
APGX-M-NW16 AL
AIM-S-NW25
WRG-S-NW25
AIGX-S-NW25
1 m Active gauge cable
2 m RS232 I/F cable (optional)
PC with RS232 interface (optional)
TIC relay box instruments
2 m Logic I/F cable
2 m Logic I/F cable


Item Ordering number Description Edwards Model 1575 Pressure Display
A
B
C
D
E
F
G

H
J
K
L
M
D38651000
D40013025
D14641000
D04851000
D02173000
D14701000
D35108000
D35513000
D35726000
D40003060
D40001030
D38650500
AGC-6 head, RS232
UK electrical supply cable
AIM-S
AIGX-S
APG-L
WRG-S
ATC-E
ATC-M
ASG
ASG adapter cable
3 m gauge cable
RS232 interface cable


Item Ordering number Description Edwards Model 1575 Pressure Display
A
B
C
D
E
F
G

H
J
D38655000
D40013025
D14641000
D04850000
D02173000
D14701000
D39616000
D40001030
D40003080
AGC-3 head
UK electrical supply cable
AIM-S
AIGX-S
APG-L
WRG-S
EXC120
3 m Active gauge cable
EXC120 adapter cable


Item Ordering number Description Edwards Model 1575 Pressure Display
A
B
C
D
E
F
G
D38660000
D40013025
W65512811
W60042811
D02173000
W40003050
D40001030
TIC inst 3 head RS232
2 m UK mains cable
APGX-M-NW16 AL
AIM-S-NW25
WRG-S-NW25
AIGX-S-NW25
1 m Active gauge cable



Item Ordering number Description Edwards Model 1575 Pressure Display
A
B
C
D
E
F
G

H
D38655000
D40013025
D14641000
D02171000
D04847000
D02999390
D04847060
D40001030
AGC-3 head
UK electrical supply cable
AIM-S
APG-M
IGC Ebeam, BOC Edwards
Ion gauge tube
Ion gauge cable
3 m Active Gauge Cable


Item Ordering number Description Edwards Model 1575 Pressure Display
A
B
C
D
E
D39556000
D40013025
D35726000
D40003060
D40001030
ADD
UK electrical supply cable
ASG
ASG adapter cable