Edwards Logo

Edwards AGC Active Gauge Controllers

Edwards AGC Active Gauge Controllers

The Active Gauge Controller (AGC) is the world's first truly universal intelligent vacuum gauge controller. Models are available to drive three or six active gauges of any type. There are versions available with either a single or triple pressure display as well as versions which accommodate capacitance manometers. Control functions are set using a simple menu system and are refined after switching off the power. Full remote control or simple data logging is possible using the RS232 interface and a Windows(tm) based software driver is available.

Edwards AGC Active Gauge Controllers

Features & benefits
  • Universal vacuum gauge controller - Can drive any combination of BOC Edwards Active gauges including Pirani linear Pirani thermocouple, strain inverted magnetron, wide range gauge and ion gauges as well as optional capacitance manometer support
  • Relay options - AlI models have six solid state switches rated at 40 V d.c. 100 mA There is also a choice of an internal card with six changeover relays rated at 240 V 3 A or an external DIN rail mounted module with six 240 V 5 A relays.
  • Automatic range switching and gauge protection - Two or more heads which cover particular pressure ranges may be linked to give automatic continuous indication over their combined pressure ranges. This feature also protects gauges that would otherwise be damaged if switched on at high pressures *
  • Automatic identification of gauge head type - Simply plugging in the gauge allows automatic identification and range scaling.
  • Remote control - Full remote control of all AGC functions or simple data logging of pressures is available through the RS232 option. A Windows based software driver is available which allows the AGC to communicate with a wide range of Windows based software packages such as spreadsheets, databases graphical display/control systems etc.
  • Capacitance manometer versions Capacitance manometers requiring a +/- 15 V power supply (BOC Edwards 600 series Barocels) should be used with CM versions of the Active Gauge Controller. A maximum of three such heads can be connected as well as all types of Active gauge
  • Universal power supply operation The AGC will accept voltages between 90 and 265 V and frequencies between 45 and 70 Hz without the need for user adjustment

Edwards AGC Active Gauge Controllers

TECHNICAL DATA

Power supply
Input voltage range: 90 to 265 V a.c.
Input frequency range: 45 to 70 Hz
Mains supply socket: IEC 320
Temperature range
Operating: 0 to +40 °C
Storage: -20 to +70 °C
Relative humidity range: 10 to 90%
(non condensing)
Standards
Electronic design: EN 61010-1
electromagnets compatibility: EN 61326 (Class B Emissions)
Enclosure rating: 1P205
Chart recorder outputs
Active gauges: 2 to 1 0 V d.c.
Capacitance manometers: 0 to 10 V d.c.
standard relays
6 open collector Transistor outputs
Voltage (maximum): 40 V d.c.
Current (maximum): 100 mA
Optional relay board Voltage (maximum): 6 electromagnetic relay outputs
Voltage (maximum): 240 V a.c.
Current (maximum): 3 A (non-inductive load)
Optional DIN rail mounting: 6 electromagnetic relay outputs
relay unit
Voltage (maximum): 240 V a.c.
Current (maximum): 5 A (non-inductive load)
Dimensions: Half 19" rack. 2U
Weight: 2.4 kg

Edwards AGC Active Gauge Controllers


Edwards AGC Active Gauge Controllers

Product Description

Edwards AGC Active Gauge Controllers

Ordering Number
CM versions can accept 600, 622 and 655 capacitance manometers as well as active gauges
AGC single display 6 head
AGC single display 6 head CM
AGC single display RS232 6 head
AGC single display RS232 6 head CM
AGC triple display RS232 6 head
AGC triple display RS232 6 head CM
AGC relay expansion board
DIN mounting relay unit
Half 19 inch rack blanking kit
Half 19 inch rack joining kit
Windowstm software driver

Spares and accessories
Active gauge cables
(including FCC68/RJ45 compatible connection at both ends)
0.5m
1m
3m
5m
10m
15m
25m
50m
100m
Non-standard lengths and screened cables available on request
Barocel capacitance manometer adapter cables
600 series (screw terminal) to female – FCC68/RJ45, 0.5m
600 series to female FCC68/RJ45, 0.5m
600/655 series to ('D' connector) to female FCC68/RJ45, 0.5m
Interface cables
Terminates in 25 way D (female)
Terminates in 9 way D (female)
Turbomolecular pump controller interface cables
EXC100 to female FCC68/RJ45, 0.5m
EXC120 to female FCC68/RJ45, 0.5m
EXC300 to female FCC68/RJ45, 0.5m
Mains cables
2 m UK plug
2 m USA plug
2 m Northern European plug

D38654000
D38653000
D38651000
D38650000
D38661000
D38660000
D38651800
D38504110
D04830301
D04830302
D38662800




D40001005
D40001010
D40001030
D40001050
D40001100
D40001150
D40001250
D40001500
D40001999


D40003010
D40003030
D40003050

D38650400
D38650500

D40003070
D40003080
D40003090

D40013025
D40013120
D40013030